• Home
  • Browse
    • Current Issue
    • By Issue
    • By Author
    • By Subject
    • Author Index
    • Keyword Index
  • Journal Info
    • About Journal
    • Aims and Scope
    • Editorial Board
    • Publication Ethics
    • Peer Review Process
  • Guide for Authors
  • Submit Manuscript
  • Contact Us
 
  • Login
  • Register
Home Articles List Article Information
  • Save Records
  • |
  • Printable Version
  • |
  • Recommend
  • |
  • How to cite Export to
    RIS EndNote BibTeX APA MLA Harvard Vancouver
  • |
  • Share Share
    CiteULike Mendeley Facebook Google LinkedIn Twitter
Journal of Food and Dairy Sciences
arrow Articles in Press
arrow Current Issue
Journal Archive
Volume Volume 16 (2025)
Volume Volume 15 (2024)
Volume Volume 14 (2023)
Volume Volume 13 (2022)
Volume Volume 12 (2021)
Volume Volume 11 (2020)
Volume Volume 10 (2019)
Volume Volume 9 (2018)
Volume Volume 03 (2018)
Volume Volume 8 (2017)
Volume Volume 7 (2016)
Volume Volume 6 (2015)
Volume Volume 5 (2014)
Volume Volume 4 (2013)
Volume Volume 3 (2012)
Issue Issue 12
Issue Issue 11
Issue Issue 10
Issue Issue 9
Issue Issue 8
Issue Issue 7
Issue Issue 6
Issue Issue 5
Issue Issue 4
Issue Issue 3
Issue Issue 2
Issue Issue 1
Volume Volume 2 (2011)
Volume Volume 1 (2010)
Volume Volume 34 (2009)
Volume Volume 33 (2008)
Volume Volume 32 (2007)
Volume Volume 31 (2006)
Volume Volume 30 (2005)
Volume Volume 29 (2004)
Volume Volume 28 (2003)
Volume Volume 27 (2002)
Volume Volume 26 (2001)
Volume Volume 25 (2000)
Abd El Aziz, M., Abo El Enien, K. (2012). COMPARATIVE STUDY BETWEEN PECTROPHOTOMETRIC AND HPLC METHODS USED FOR IODINE EXTRACTION IN MILK AND SOME DAIRY PRODUCTS. Journal of Food and Dairy Sciences, 3(4), 247-258. doi: 10.21608/jfds.2012.75371
Magda Abd El Aziz; Karima Abo El Enien. "COMPARATIVE STUDY BETWEEN PECTROPHOTOMETRIC AND HPLC METHODS USED FOR IODINE EXTRACTION IN MILK AND SOME DAIRY PRODUCTS". Journal of Food and Dairy Sciences, 3, 4, 2012, 247-258. doi: 10.21608/jfds.2012.75371
Abd El Aziz, M., Abo El Enien, K. (2012). 'COMPARATIVE STUDY BETWEEN PECTROPHOTOMETRIC AND HPLC METHODS USED FOR IODINE EXTRACTION IN MILK AND SOME DAIRY PRODUCTS', Journal of Food and Dairy Sciences, 3(4), pp. 247-258. doi: 10.21608/jfds.2012.75371
Abd El Aziz, M., Abo El Enien, K. COMPARATIVE STUDY BETWEEN PECTROPHOTOMETRIC AND HPLC METHODS USED FOR IODINE EXTRACTION IN MILK AND SOME DAIRY PRODUCTS. Journal of Food and Dairy Sciences, 2012; 3(4): 247-258. doi: 10.21608/jfds.2012.75371

COMPARATIVE STUDY BETWEEN PECTROPHOTOMETRIC AND HPLC METHODS USED FOR IODINE EXTRACTION IN MILK AND SOME DAIRY PRODUCTS

Article 5, Volume 3, Issue 4, April 2012, Page 247-258  XML PDF (884.15 K)
Document Type: Original Article
DOI: 10.21608/jfds.2012.75371
View on SCiNiTO View on SCiNiTO
Authors
Magda Abd El Aziz; Karima Abo El Enien
Dairy Chemistry Dept., Animal Production Res. Institute, Agric. Res. Center, Ministry of Agric.
Abstract
Determination of iodine in milk and its products is very important from the  nutritional view point. Simple and rapid extraction methods were evaluated and validated  for determining iodine in milk and some dairy products by Spectrophotometric  method  and HPLC methods . Iodine in milk ( raw and pasteurized), white soft cheese and yoghurt were extracted by three methods first, with ammonium persulfate, second with acetic and nitric acid, third with alkaline ashing . After extraction, the reaction of As3+-Ce4+ was performed at 32 ºC, the transmission was measured spectrophotometrically at 420 nm. The results showed the precision of the ammoniumpersulfate method for all samples (CV< 4%) are higher than that of the alkaline ashing and acetic acid with nitric acid methods. The recoveries of iodine added to samples in range 91- 97 %, 93 – 120 % for extraction of milk iodine with ammonium persulfate, mixture of acetic acid with nitric acid, respectively, are higher compared with alkaline ashing . In addition ,  the linear coefficient(r) for ammonium persulfate is 0.9994 better than mixture of acetic with nitric acid and alkaline ashing methods. The Comparison between spectrophotometric and HPLC methods for iodine analysis was carried on raw and pasteurized milk after extraction with  the three extraction methods. The data showed  reasonably strong correlation between results from both of those analytical methods ( r =  0.9641, .9682  0.9533  for ammo. persulfate , acetic acid with nitric acid and alkaline ashing respectively.It was found that method HPLC gave comparable results to spectrophotometric method.
Keywords
Iodine; Milk; cheese; yoghurt; Ammo. persulfate; acetic with nitric acid; ashing; Spectrophotometery; HPLC
Statistics
Article View: 150
PDF Download: 557
Home | Glossary | News | Aims and Scope | Sitemap
Top Top

Journal Management System. Designed by NotionWave.